Rapid Determination of Seismic Moment and Radiated Energy - Region: Central Italy  Event List

Earthquake Location (from: INGV id: 43928092 ingv)
Region: Campi Flegrei - 2025-09-01 00:02:11 (UTC)

Laboratory of Seismology (Distav, University of Genoa) - ID: 250901000211
Posted on: 2025-09-19 07:13:47

RSNI Logo



Seismic Moment (Log): 11.94 ± 0.66
Radiated Energy (Log): 5.64 ± 1.17
Moment Magnitude MW: 1.90
Local Magnitude ML IT16: 1.28 ± 0.44
Apparent Stress [Pa]: 1.59e+4

Station Net Loc. Chan. Hypo dist. [km] ML IT16 PGA Z [cm/s2] PGA NS [cm/s2] PGA EW [cm/s2] PGV Z [cm/s] PGV NS [cm/s] PGV EW [cm/s] Log(Mo) Log(Er) Used(1)
COLB IV HH 0.8 0.8 4.261000 8.587000 5.921000 0.042880 0.049280 5.921000 - - -
CSOB IV HH 1.2 1.6 8.906000 9.004000 13.030000 0.076680 0.142400 13.030000 13.06 7.48 -
CPIS IV HH 1.5 0.7 1.690000 1.655000 1.258000 0.018320 0.013470 1.258000 11.14 4.27 -
POZS IT HN 1.5 0.4 0.204900 0.205200 0.184300 0.004626 0.003760 0.184300 - - -
CSTH IV HH 1.6 0.9 0.911300 1.257000 1.358000 0.013460 0.014050 1.358000 12.20 6.43 -
POZT IT HN 1.7 0.2 0.130600 0.096650 0.051730 0.001499 0.002191 0.051730 - - -
CPOZ IV HH 1.9 0.5 0.176800 0.267100 0.032410 0.003774 0.009698 0.032410 - - -
BAN IT HN 2.3 0.7 0.316100 0.388400 0.314700 0.004059 0.005892 0.314700 - - -
CAWE IV HH 2.6 0.7 0.174700 0.161600 0.142500 0.003894 0.003448 0.142500 11.50 4.72 -
CBAG IV HH 3.1 -9.0 0.000000 0.000000 0.336200 0.000000 0.000000 0.336200 - - -
BCLI IT HN 5.8 1.2 0.074190 0.039180 0.031160 0.001640 0.001983 0.031160 - - X
CML IT HG 21.6 1.7 0.073410 0.131100 0.088660 0.001427 0.001476 0.088660 - - X
SNAL IV HH 90.7 1.9 0.000494 0.000430 0.000329 0.000069 0.000117 0.000329 - - X
RNI2 IV HH 98.3 1.6 0.000248 0.000458 0.000453 0.000037 0.000044 0.000453 - - X
SGO IV HH 102.5 1.3 0.001343 0.006556 0.005210 0.000024 0.000046 0.005210 11.82 5.30 X
CIGN IV HH 112.7 1.4 0.000117 0.000154 0.000145 0.000028 0.000022 0.000145 - - X
(1) Used for the local magnitude calculation


Credits and Copyright
RAMONES (Rapid Assessment of MOmeNt and Energy Service) service is designed, developed and maintained by the seismological group of the University of Genoa. The source parameters are estimated using features extracted directly from recordings, following methodologies developed through scientific collaborations between the University of Genoa, the German Research Centre for Geosciences (GFZ-Potsdam), the University of Naples, and the Italian National Institute of Geophysics and Vulcanology (INGV).
If you use these data, please cite the original paper: doi:10.1785/0220200348
Reproduction is authorised only if the source is cited in a complete and comprehensive way.